UPS (UPS) - 20KVA/20KW UPS 3:3 requires 16,18,20 an external battery

UPS (UPS) - 20KVA/20KW UPS 3:3 requires 16,18,20 an external battery

Model
YDC3320H
Code
#01391
Brand
KSTAR
7888.84₾

Create account to see your price.

Only a few left
  • ✓ Official warranty
  • ✓ Delivery across Georgia
  • ✓ Card payment or installments

Bulky item — return transport is at the buyer's expense; we will tell you the collection cost before you order.

Return policy

Description

The YDC3320H requires a constant voltage of ±96/108/120 V and, accordingly, 16/18/20 series-connected 12V batteries. YDC3320 H series uninterruptible power supplies are high-reliability three-phase UPS units with isolated input and output voltages, which protects the connected equipment from damage caused by deviations of electrical parameters in the mains. When the power fails, the UPS switches the load to backup power without delay. Batteries with a capacity of up to 200 ampere-hours can be connected externally to the UPS, providing long autonomous operation of the equipment. If necessary, UPS units can be connected in parallel to increase the system capacity. Used to power critical three-phase loads such as industrial automation systems, server rooms and data centers, financial transaction systems, medical equipment and more. Features • Double conversion • Pure sine wave • Zero transfer time to backup power • Interfaces: REPO, RS232, RS485, USB, SNMP / Dry contact slot • N+1 parallel operation capability • Generator compatibility • Multi-level protection function • Start-up video instructions: video link Warranty conditions The device must be installed by a qualified electrical engineer, in compliance with all rules stated in the official installation manual. The device must be connected to a grounding loop built to the standard defined by Georgian legislation. The device must be protected from industrial and natural dust, and the temperature and humidity must meet the requirements stated in the technical documentation. After installation, inspection and commissioning are carried out by an Intelcom Group employee. Switching on the device without an Intelcom Group representative is not permitted. If you use a generator whose output signal is distorted, the UPS must be switched to generator mode. For the specific warranty conditions that apply to uninterruptible power supplies, see here

Specifications

Backup runtimeLong - requires batteries
Apparent power20000 VA
Active power20000 W
Number of phases3
Input voltage range208 V - 478 V
Rated output voltage380 V
Input frequency range45 Hz - 55 Hz
Output frequency50 ±0.1% Hz
Built-in battery capacityNo
Parallel operation capabilityYes
With built-in transformerNo
WaveformPure sine wave
Efficiency94.5 %
Bypass modeYes
Auto restart on power recoveryYes
Generator compatibilityYes
Cold startYes
Self-diagnosticsYes
LCD screenYes
USB management portYes
SNMP card slotYes
TerminalYes
Number of socketsNo
Socket typeNo
Operating temperature0 °C - 40 °C
Weight64 kg